UPC Code |
037332119247 |
UPS Type |
Line-Interactive |
Input Phase |
Single-Phase |
Rated input current (Maximum Load) |
10A |
Nominal Input Voltage(s) Supported |
120V AC |
UPS Input Connection Type |
5-15P |
Input Circuit Breakers |
10A |
UPS Input Cord Length (ft.) |
10 |
Recommended Electrical Service |
15A 120V |
Output Capacity (VA) |
500 |
Output Capacity (kVA) |
0.5 |
Output Capacity (Watts) |
300 |
Output Capacity (kW) |
0.3 |
Output Capacity Details |
4.2A @ 120V. (LINE MODE) 120% @ 5 minutes; (BATTERY MODE) 120% @ 5 seconds |
Power Factor |
0.6 |
Nominal Voltage Details |
120V sinusoidal in line mode and 120V PWM in battery mode |
Frequency Compatibility |
60 Hz |
Frequency Compatibility Details |
Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. |
Output Voltage Regulation (Line Mode) |
-14%, +16% |
Output Voltage Regulation (Battery Mode) |
+/- 5% |
UPS Output Receptacles (Surge Suppression Only) |
5 UPS outlets, 1 surge-only outlet |
Load Management Receptacles |
One switchable single-outlet 5-15R load bank |
Output AC Waveform (AC Mode) |
Sine wave |
Output AC Waveform (Battery Mode) |
PWM sine wave |
Nominal Output Voltage(s) Supported |
120V |
Output Receptacles |
(6) 5-15R |
Individually Controllable Load Banks |
Yes |
Battery Type |
Valve Regulated Lead Acid (VRLA) |
Runtime Full Load (min.) |
3 min. (300W) |
Runtime Half Load (min.) |
14 min. (150W) |
DC System Voltage (VDC) |
12 |
Battery Recharge Rate (Included Batteries) |
Less than 12 hours to 90% |
Battery Access |
Battery access door |
Internal UPS Replacement Battery Cartridge |
IMPORTANT BATTERY REPLACEMENT INFORMATION > Use Tripp Lite RBC12V-1U replacement battery for SMART500RT1U models with Series Number AG-03AA listed on the UPS nameplate (sold starting in 2021); For all prior versions of SMART500RT1U, use Tripp Lite RBC62-1U replacement battery; Contact Tripp Lite customer service for additional information |
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 90 ( 5%). Input voltage range of 90 to 139 |
Undervoltage Correction |
Input voltages between 90 and 105 ( 5%) are boosted by 14% |
Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation |
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch |
Audible Alarm |
Audible alarm indicates power-failure, overload and low-battery conditions |
LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
EMI / RFI AC Noise Suppression |
Yes |
AC Suppression Joule Rating |
567 |
AC Suppression Response Time |
Instantaneous |
Primary Form Factor |
Rackmount; Tower |
Rack Height |
1U |
Included Mounting Accessory Description |
Included mounting brackets provide front-rail installation in 2 or 4 post racks, plus upright tower configurations |
Installation Form Factors Supported with Included Accessories |
2 post 19 inch rackmount; 2 post front mount; 4 post 19 inch rackmount; Tower |
Minimum Required Rack Depth (inches) |
15 |
Primary UPS Depth (mm) |
286 |
Primary UPS Height (mm) |
44 |
Primary UPS Width (mm) |
440 |
Shipping Dimensions (hwd / in.) |
4.20 x 15.70 x 21.30 |
Shipping Weight (lbs.) |
21.25 |
UPS Housing Material |
Steel |
UPS Power Module Dimensions (hwd, in.) |
1.73 x 17.32 x 11.26 |
UPS Power Module Weight (kg) |
7.18 |
UPS Power Module Weight (lbs.) |
15.84 |
Unit Dimensions (hwd / in.) |
1.730 x 17.320 x 11.260 |
Unit Weight (lbs.) |
15.800 |
Operating Temperature Range |
32° to 104°F (0° to 40°C) |
Storage Temperature Range |
5° to 122°F (-15° to 50°C) |
Relative Humidity |
0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) |
48 |
AC Mode Efficiency Rating (100% Load) |
97% |
AC Economy Mode Efficiency Rating (100% Load) |
0.97 |
Operating Elevation |
0-6562 ft. (0-2000 m) |
Audible Noise |
45 dBA maximum, front side 1m |
Network Management Cards |
WEBCARDLXE |
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions |
PowerAlert Software |
For local monitoring via the UPS s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
Communications Cable |
USB and DB9 cabling included |
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
Network Management Card Description |
Network management card optional |
Communications Interface |
DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
Transfer Time |
4-6 ms typical ( < 10 ms max) |
Low Voltage Transfer to Battery Power (Setpoint) |
90 |
High Voltage Transfer to Battery Power (Setpoint) |
139 |
Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
High Availability UPS Features |
Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection; Auto Probe Monitoring (requires WEBCARDLXE) |
Grounding Details |
Back panel grounding lug |
UPS Applications |
High-End Desktop/Small Network; Retail/Point of Sale; Hospitality |
Product Certifications |
CSA (Canada); ICES (Canada); NOM (Mexico); UL 1778 |
Product Compliance |
ENERGY STAR Qualified; FCC Part 15 Class B (USA); RoHS |
Product Warranty Period (Worldwide) |
2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty. |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) |
$250,000 Ultimate Lifetime Insurance |