UPC Code |
037332119247 |
UPS Type |
Line-Interactive |
Output Volt Amp Capacity (VA) |
500 |
Output Watt Capacity (Watts) |
300 |
Nominal Voltage Details |
120v nominal output in battery mode |
Frequency Compatibility |
60 Hz |
Output Voltage Regulation (Line Mode) |
-15%, +13% |
Output Voltage Regulation (Battery Mode) |
+/- 5% |
UPS Output Receptacles (Surge Suppression Only) |
6 UPS outlets, 1 surge-only outlet |
Load Management Receptacles |
One switchable single-outlet 5-15R load bank |
Output AC Waveform (AC Mode) |
Sine wave |
Output AC Waveform (Battery Mode) |
PWM sine wave |
Nominal Output Voltage(s) Supported |
110V; 115V; 120V |
Output Receptacles |
(6) 5-15R |
Individually Controllable Load Banks |
Yes |
Rated input current (Maximum Load) |
12A (Maximum input with 300W UPS and 1140W surge-only loads) |
Nominal Input Voltage(s) Supported |
120V AC |
UPS Input Connection Type |
5-15P |
Input Circuit Breakers |
15A |
UPS Input Cord Length (ft.) |
10 |
Recommended Electrical Service |
15A 120V |
Input Phase |
Single-Phase |
Full Load Runtime (min.) |
3.2 min. (300w) |
Half Load Runtime (min.) |
14.6 min. (150w) |
DC System Voltage (VDC) |
12 |
Battery Recharge Rate (Included Batteries) |
Less than 16 hours from 10% to 90% (typical, full load discharge) |
Internal UPS Replacement Battery Cartridge |
RBC62-1U |
Battery Access |
Battery access door |
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Expandable Runtime |
No |
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 90 |
Undervoltage Correction |
Input voltages between 90 and 105 are boosted by 14% |
Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation |
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
Audible Alarm |
Audible alarm indicates power-failure, overload and low-battery conditions |
LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
EMI / RFI AC Noise Suppression |
Yes |
AC Suppression Joule Rating |
567 |
AC Suppression Response Time |
Instantaneous |
Included Mounting Accessory Description |
Included mounting brackets provide front-rail installation in 2 or 4 post racks, plus upright tower configurations |
Installation Form Factors Supported with Included Accessories |
2 post 19 inch rackmount; 4 post 19 inch rackmount; Tower |
Minimum Required Rack Depth (inches) |
14.26 |
Primary Form Factor |
Rackmount |
Primary UPS Depth (mm) |
286 |
Primary UPS Height (mm) |
44 |
Primary UPS Width (mm) |
440 |
Rack Height |
1U |
Shipping Dimensions (hwd / in.) |
15.40 x 4.80 x 22.10 |
Shipping Weight (lbs.) |
20.90 |
UPS Housing Material |
Steel |
UPS Power Module Dimensions (hwd, in.) |
1.73 x 17.32 x 11.26 |
UPS Power Module Weight (kg) |
7.98 |
UPS Power Module Weight (lbs.) |
17.6 |
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity |
0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) |
44 |
AC Mode Efficiency Rating (100% Load) |
96% |
Communications Interface |
USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
Network Management Cards |
SNMPWEBCARD; TLNETCARD; WEBCARDLX |
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions |
PowerAlert Software |
For local monitoring via the UPS's built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
Communications Cable |
USB and DB9 cabling included |
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
Network UPS Tools Compatibility |
NUT compatible. See full list of compatible Tripp Lite products at http://www.networkupstools.org/stable-hcl.html'manufacturer=Tripp Lite |
Transfer Time |
4-7 milliseconds |
Low Voltage Transfer to Battery Power (Setpoint) |
90 |
High Voltage Transfer to Battery Power (Setpoint) |
140 |
Grounding Lug |
Back panel grounding lug |
Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
High Availability UPS Features |
Hot swappable batteries |
UPS Certifications |
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico) |
Product Warranty Period (Worldwide) |
2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty. |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) |
$250,000 Ultimate Lifetime Insurance |